Dekker Vacuum Technologies, Inc. – DuraVane/12 5
Discharge Piping
Do not discharge the exhaust gases from the pump or system into the area where the system is
installed. Vapors pulled over from the process could be hazardous. Discharge piping should be at least
the size of the pump discharge. DEKKER recommends the installation of a dripleg with tee on the
discharge line, to prevent any condensed vapors discharged by the pump from draining back into the
pump oil reservoir. See diagram below.
For pumps and systems operating in parallel on a common discharge, we recommend the installation
of a suitable check valve close to the discharge. When discharging more than one unit in a common
discharge line and/or over a long distance, oversize pipe accordingly.
Discharge piping diagrams
Following are the inlet and discharge connection sizes for the different pump models:
THEORY OF OPERATION
DuraVane lubricated rotary vane pumps are single-stage pumps with an integrated closed loop oil
circulation system. The construction is heavy-duty and compact, resulting in a small footprint. The high-
tech vane material provides 50,000 hours vane life. The pumps have an internally mounted inlet check
valve. Pumps are direct driven with flange-mounted motor. The standard design is air-cooled with a
high-efficiency multi-stage exhaust filter that results in 99.9% oil mist removal.
Pump can operate with closed suction without overheating