INSTALLATION INSTRUCTIONS
10
If it becomes necessary to replace the gas tap, proceed as follows:
• Disconnect the appliance as described above.
• Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the
fixing screws.
• When fitting a new tap, ensure that a new gasket is used.
• Re-connect the gas tap, check for gas soundness and reassemble the hob.
TECHNICAL DATA
ELECTRICAL DETAILS
Rated Voltage 230V ac 50Hz
Supply Connection 13A (double pole switched fused outlet with 3mm contact gap)
Power Input 0.008 to 0.02kW (depending on model)
Mains supply lead 3 x 0.75mm2 Type RR-F <HAR> marked
GAS DETAILS
Connection Rp ½ (ISO R7)
Type Natural Gas (20.9 mbar) – alternative LPG G30 (28-30 mbar)
[Town Gas G110 – 120 (8 mbar) to order]
BURNER TYPES AND POWER INPUTS : kW
Model Large Medium Small Wok Fish Total
Max / Min Max / Min Max / Min Max / Min Max / Min KW
AS9.1TCAL-BX
3.0 / 0.7 1.75 / 0.4 1.0 / 0.35 3.5/1.7 - 11.0
B72TCBL-BX
- 1.75 / 0.4 1.0 / 0.35 3.5/1.7 - 8
B77TCBL-BX
3.0 / 0.7 1.75 / 0.4 1.0 / 0.35 3.5/1.7 - 11.0
JET SIZING CONVERSION TABLE: NATURAL GAS / LPG
Model Large Medium Small Wok Fish
NG / LPG NG / LPG NG / LPG NG / LPG NG / LPG
AS9.1TCAL-BX
1.15 / 0.85 0.97 / 0.65 0.72 / 0.50 1.35/0.72 -
B72TCBL-BX
- 0.97 / 0.65 0.72 / 0.50 1.35/0.72 -
B77TCBL-BX
1.15 / 0.85 0.97 / 0.65 0.72 / 0.50 1.35/0.72 -