o This appliance must be wired into a 35 A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. It should
not be located above the appliance and no more than 1.25m
away from it.
o The spur outlet must still be accessible even when your hob is
located in its operating position.
o Cable type: H05 RRF 3 core x 6 mm²
Connecting the mains supply cable
o The mains terminal block is located on the underside of the hob
and the terminals are accessible by removing the terminal block
cover by removing the cover screw.
o The brass links must be positioned as marked in the appropriate
diagram and once established ALL terminal screws must be
tightened down firmly.
o If when the hob is first switched on, only two of the zones
work, you should recheck that the terminal screws are all
fully tightened between the links. This should be done
before contacting the Baumatic Customer Care
Department.
o IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the hob is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.